Views: 0 Author: Site Editor Publish Time: 2026-05-18 Origin: Site
Figure 1: Trauhui 2.4/3.5 Distal Radius Volar Plates Long
Distal radius fractures are among the most common orthopedic injuries, but increasingly complex fracture patterns—especially those extending into the radial shaft—require more versatile fixation solutions. The 2.4/3.5 Distal Radius Volar Plates Long is designed to meet this demand, offering surgeons a more efficient and comprehensive approach to fracture management.
Figure 2: Trauhui 2.4/3.5 Distal Radius Volar Plates Long
Traditional volar plates are typically limited to distal radius fixation. In cases where the fracture propagates proximally into the shaft, surgeons often face the challenge of using multiple implants, which can increase operative time and soft tissue disruption.
The 2.4/3.5 Distal Radius Volar Plates Long addresses this limitation by allowing simultaneous fixation of the distal radius and radial shaft with a single plate. This expanded indication makes it particularly valuable in treating complex or combined fracture patterns while simplifying the overall surgical strategy.
This long plate system combines 2.4 mm distal fixation with 3.5 mm shaft fixation, delivering both precision and strength where they are needed most. The design supports stable fixation across a longer anatomical span, helping maintain alignment and promoting reliable healing.
Broader clinical application for complex fracture patterns
Reduced need for multiple implants, minimizing surgical steps
Optimized fixation strength from distal to shaft region
Streamlined workflow in the operating room
Improved inventory efficiency for hospitals and distributors
Early clinical application of the long plate has demonstrated promising results. Postoperative X-ray images show stable fixation, accurate alignment, and effective coverage of both distal and shaft regions.
Figure 3: X Ray
Figure 4: X Ray
Figure 5: X Ray
Alongside the long plate, we continue to offer the 2.4 Distal Radius Volar Plates (8-hole head) and 2.4 Distal Radius Volar Plates (9-hole head). These plates are specifically designed for standard distal radius fractures and remain a reliable choice for routine clinical cases. By providing both standard and extended plate options, we deliver a more comprehensive fixation system to meet diverse clinical needs.
Figure 6: Trauhui 2.4 Distal Radius Volar Plates (8-hole head)
Figure 7: Trauhui 2.4 Distal Radius Volar Plates (9-hole head)
As orthopedic trauma care continues to evolve, implant systems must keep pace with increasingly complex indications. The 2.4/3.5 Distal Radius Volar Plates Long reflects this evolution—offering enhanced versatility, efficiency, and confidence in fixation.
Extended Volar Plate for Distal Radius And Radial Shaft Fixation
Ankle Fusion Nail: A Reliable Solution for Severe Ankle Conditions
A New Approach To Patella Fracture Fixation: Anterior Patella Plates in Practice
Distal Lateral Fibular Hook Plate: A Smart Solution for Challenging Distal Fibula Fractures
Ramic Tibial Intramedullary Nail System: Advancing Modern Tibial Nailing Techniques
Trauhui Medical Makes A Brilliant Appearance at The 2025 AAOS